Activities to refurbish the BF coolers to their design flow rate and pressure characteristics in line using an in place-repair technique
Results
Description
Value before
Value after
Variance
Water flow rate, m³/hour
1,7
4,0-4,2
2,3-2,5
Pressure, bar
4,2
0,75
3,45
2021: JSC DMK (Ukraine), Oxygen Compressor Plant:
Maintenance, in-place cleaningand restoration of the volumetric and heat exchanging parameters for heat exchangers AlfaLaval TS20- MFG and Alfa Laval MA30-SFM and heat-and-utilities equipment as part of the water and air pre-cooling systemfor Air Separation Unit AKAr-40/35-4 in the Oxygen Compressor Plant.